low-smoke no(ow)-halogen flame retardatory fire resistance wirez&cable
Category:
Descriptions:
Brief product introduction
Low-smoke free-halogen flame-retardancy wire cables can produces little smoke and inno cuousgas without halogen or with little halogen when combustion.It can extremely reduce the damage to the instruments,equipment and body as the fire occurred .So, itwas widely used in the crowded public concourses such as high-rise building, large-sized library,gymnasium, commanding&dontollingbuilding for guard against blast, station, ivil airfield, passenger waiting room,emplases cultural relic,subway,underground shop,etc.
The using property of the rated voltage under 3$k plastics insulated cable and wire developed by our company,comply with therequire-ment of GB/T12706-2008,G8 5023-2008 and GB9330-88,DGJ08-93-2002.Meanwhile, its low-smoke and free-halogen property complywiththe standard of GB/T19650-12-1998,GB/T17651.1~2-1998.B页天和national technique inquiry,this type of products reach to domestic advancedlevel,Lowsmoke free-halogen flame retardancy wire cables.
The type and its specitication see Table 1
| Model | Name | Flame ratardancy grade |
| DDZ-VV DDZ-VLY DDZ-VY DDZ-VLY | Low-smoke low-halogen PVCinsulated 1ow-smoke low-halogen PVC/polyethylene sheathed fiame-retardancy power cables | A、B、C |
| DDZ-VV22 DDZ-VLV22 DDZ-VV23 DDZ-VLV23 | Low-smoke low-halogen PVCinsulated steel tape amored 1ow-smoke low-halogen PVC/polyethylene sheathed flame-retardancy power cables | |
| DDZ-VV32 DDZ-VLV32 DDZ-VV33 DDZ-VLV33 DDZ-VV42 DDZ-VLV42 DDZ-VV43 DDZ-VLV43 | Low-smoke low-halogen PVCinsulated steel thread amored 1ow-smoke low-halogen PVC/polyethylene sheathed flame-retardancy power cables | |
| DDZ-YJ(F)V DDZ-YJ(F)LV | (Irradiated)XLPE insulated 1ow-smoke 1ow-halogen PVCsheathed flame-retardancy power cabkes | A、B、C |
| DDZ-YJ(F)V22 DDZ-YJ (F)LV22 | (Irradiated)XLPE insulated steel tape armored low-smoke low-halogen PVC sheathed flame-retardancy power cabkes | |
| DDZ-YJ (F)V32 DDZ-YJ(F)LV32 DDZ-YJ(F)V42 DDZ-YJ(F)LV42 | (Irradiated)XLPE insulated steel thread 1ow-smoke low-halogen PVC sheathed flame-retardancy power cabkes | |
| DDZ-KVV DDZ-KYJ(F)V | Low-smoke low-halogen PVC/(Irradiated)XLPE insulated low-smoke Low-halogen PVC sheathed flame-retardancy cabkes | A、B、C |
| DDZ-KVV22 DDZ-KYJ(F)V22 | Low-smoke low-halogen PVC/(Irradiated)XLPE insulated steel tape armored low-smoke Low-halogen PVC sheathed flame-retardancy control cabkes | |
| DDZ-KYJ(F)VP | Low-smoke low-halogen PVC/(Irradiated)XLPE insulated copper thread mesh sereened low-smoke Low-halogen PVC sheathed flame-retardancy control cabkes | |
| DDZ-KVVP2 DDZ-KYJ(F)VP2 | Low-smoke low-halogen PVC/(Irradiated)XLPB insulated insulated steel tape sereened low-smoke Low-halogen PVC sheathed flame-retardancy control cabkes | |
| DDZ-KVV32 DDZ-KYJ (F)V32 | Low-smoke low-halogen PVC/(Irradiated)XLPE insulated steel tape low-smoke Low-halogen PVC sheathed flame-retardancy control cabkes | |
| DDZ-BV DDZ-BLV | Low-smoke low-halogen PVC insulated flame-retardancy electric wire | B、C、D |
| DDZ-BVV DDZ-BLVV | Low-smoke low-halogen PVC insulated sheathed flame-retardancy electric wire | |
| LDDZ-BVR | Low-smoke low-halogen PVC insulated flame-retardancy flexible electric wire | |
| WDZ-YJ (F)E WDZ-YJ(F)LE WDZ-YJ(F)Y WDZ-YJ (F)LY | (Irradiated)XLPE insulated 1ow-smoke free-halogen flame- retardancy polyolefin sheathed power cables | A、B、C |
| WDZ-YJ(F)E23 WDZ-YJ(F)LE23 WDZ-YJ(F)Y23 WDZ-YJ(F)LY23 | (Irradiated)XLPE insulated steel tape armored low-smoke free- halogen flame-retardaney polyolefin sheathed power cables | |
| WDZ-YJ(F)E33 WDZ-YJ (F)LE33 WDZ-YJ (F)Y33 WDZ-YJ(F)LY33 WDZ-YJ(F)E43 WDZ-YJ (F)LE43 WDZ-YJ(F)Y43 WDZ-YJ(F)LY43 | (Irradiated)XLPE insulated steel thread armored low-smoke free- halogen flame-retardaney polyolefin sheathed power cables | |
| WDZ-KYJ(F)E WDZ-KYJ(F)Y | Irradiated)XLPE insulated low-smoke free-halogen flame- retardancy polyolefin sheathed control cables | |
| WDZ-KYJ (F)E23 WDZ-KYJ (F)Y23 | ( Irradiated)XLPE insulated steel tape armored low-smoke free- halogen flame-retardancy polyolefin sheathed control cables | A、B、C |
| WDZ-KYJ(F)EP WDZ-KYJ (F)YP | (Irradiated)XLPE insulated copper thread mesh sereened low-smoke free- halogen flame-retardancy polyolefin sheathed control cables | |
| WDZ-KYJ(F)EP2 WDZ-KYJ(F)YP2 | (Irradiated)XLPE insulated copper tape sereened low-smoke free- halogen flame-retardancy polyolefin sheathed control cables | |
| WDZ-KYJ(F)E33 WDZ-KYJ(F)Y33 | (Irradiated)XLPE insulated steel thread armored low-smoke free-halogen flame-retardancy polyolefin sheathed control cables | B、C、D |
| WDZ-BYJ(F) WDZ-BLYJ(F) WDZ-BY WDZ-BLY | (Irradiated)cross-1inked type/non-cross-1inked type low-smoke free-halogen flame-retardancy polyolefin insulated electric wires | |
| WDZ-BYJ(F)E WDZ-BLYJ(F)E WDZ-BYE WDZ-BLYE | (Irradiated)cross-1inked type/non-cross-1inked type low-smoke free- halogen flame-retardancy polyolefin insulated 1ow-smoke free- halogen flame-retardancy polyolefin sheathed electric wires | |
| WDZ-BYJ(F)R WDZ-BYR | (Irradiated)cross-1inked type/non-cross-1inked type low-smoke free-halogen flame-retardancy polyolefin insulated flexible electric wires | |
| WDZN-YJ(F)E WDZN-YJ(F)Y | Copper core(Irradiated)XLPE insulated armored 10w-smoke free-halogen flame-retardancy polyolefin sheathed fire resistance power cables | A、B、C |
| WDZN-YJ(F)E23 WDZN-YJ (F)Y23 | Copper core(Irradiated)XLPE insulated steel thread armored low-smoke free-halogen flame-retardancy polyolefin sheathed fire resistance power cables | |
| WDZN-YJ(F)E33 WDZN-YJ F)Y33 WDZN-YJ(F)E43 WDZN-YJ F)Y43 | Copper core(Irradiated)XLPE insulated steel thread armored 1ow-smoke free-halogen flame-retardancy polyolefin sheathed fire resistance power cables | A、B、C |
| WDZN-KYJ(F)E WDZN-KYJ(F)Y | (Irradiated)XLPE insulated 1ow-smoke free-halogen flame- retardancy polyolefin sheathed fire resistance control cables | |
| WDZN-KYJ(F)E23 WDZN-KYJ(F)Y23 | Irradiated)XLPE insulated 1ow-smoke free-halogen flame- retardancy polyolefin sheathed fire resistance control cables | |
| WDZN-KYJ(F)EP WDZN-KYJ(F)YP | (Irradiated)XLPE insulated copper thread mesh screened 1ow-smoke free- halogen flame-retardancy polyolefin sheathed fire resistance control cables | |
| WDZN-KYJ(F)EP2 WDZN-KYJ(F)YP2 | (Irradiated)XLPE insulated copper tape screened low-smoke free-halogen flame-retardancy polyolefin sheathed fire resistance control cables | |
| WDZN-KYJ (F)EP33 WDZN-KYJ (F)YP33 | (Irradiated)XLPE insulated steel thread low-smoke free-halogen flame-retardaney polyolefin sheathed fire resistance control cables | |
| WDZN-BYJ(F) WDZN-BY | (Irradiated)cross-1inked type/non-cross-1inked type low-smoke free-halogen flame-retardancy polyolefin sheathed fire resistance electric wires | B、C、D |
| WDZN-BYJ (F)E WDZN-BYE | (Irradiated)cross-1inked type/non-cross-1inked type low-smoke free-halogen flame-retardancy polyolefin insulated low-smoke free-halogen flame-retardancy polyolefin sheathed fire resistance electric wires | |
| WDZN-RYJ (F)R WDZN-BYR | ( Irradiated)cross-linked type/non-cross-1inked type 1ow-smoke free-halogen flame-retardancy polyolefin insulated low-smoke free-halogen flame- retardancy polyolefin sheathed fire resistance flexible electric wires |
Grade and choose for the using location
1.Low-smoke free/low-halogen types divides into four kinds:special class,first class, second class, third classaccording to theusingproperty, fire damage and evacuation&extinguishment difficulty,Meanwhile, it aslo complieswith the requirement of Table3-2.
2.When they are laying in colligation,the low-smoke free/low-halogen wires and cables should be flame-retardancyrypes whose grades comply with table 3-3and table 3-4. lf the location needs intergrated lines and constant electricity under the outside fire,they should be fire resistance types.
Table 2 the grade choice to the flameretardancy property of electrical wires
| Applicable place | Section area | Flame retardancy grade |
| Special class | 50mm²and above | B class |
| 35mm²and above | C class | |
| First class | 50mm²and above | C class |
| 35mm²and above | D class | |
| Second class third class | Al1 area | D class |
Table 3 the grade choice to the flame-retardancy property of cables
| Applicable place | Flame retardancy grade |
| Special class | A class |
| First class | B class |
| Second class third class | c class |
Key words: