Type KVVP₂,ZR-KVVP₂450/750V Copper Conductor PVC Insulated and Sheathed Control Cable with Copper Tape Shield Type KVVP₂,ZR-KVVP₂450/750V Copper Conductor PVC Insulated and Sheathed Control Cable with Copper Tape Shield

Category:


Model and name:see table 1

ModelNameMain applications
KVVCopper conductor PVC Insulated and sheathed control cableFor laying indoors,in trenches and in ducsts, for fixed installation
KVVPCopper conductor PVC Insulated &sheathed copper wire braiding sereened control cable

For laying indoors,in trenches and in ducsts,

for fixed installation

KVVP2Copper conductor PVC Insulated and sheathed control cable with steel tape shieldFor laying indoors,in trenches and in ducsts, for fixed installation
KVV22Copper conductor PVC Insulated and sheathed control cable with steel tap armour

For laying indoors,in ducsts and in ground,

able towithstand heavier mechanical

foree,and for fixed installation

KVVRCopper conductor PVC Insulated flexible control cableFor laying indoors,movable and flexible
ZC-KVVRPCopper conductor PVC insulated &sheathed copper wire braiding sereened flexible control cableFor laying indoors with capability of moving and screening
ZC-KVVCopper conductor PVC Insulated and sheathed flame retardant control cable

For laying indoors in trenches,inducts and

for fixedinstallation,the cable should

be flame retardance

ZC-KVVP2

Copper conductor PVC Insulated and sheathed flame retardant control cable with

steel tape shield

For laying indoors in trenches,inducts and

for fixedinstallation,the cable should

be flame retardance

ZC-KVV22

Copper conductor PVC Insulated and sheathed flameretardant control cable with

steel tap armour

For laying indoors,in ducsts and in ground,able

to withstand heavier mechanical foree,and

for fixed installation

ZC-KVVRCopper conductor PVC Insulated and sheathed flameretardant flexible control cableFor laying indoors,and the cable should be flame-retardant flexible and movable

Construction size and Properties of cables
Type KVV,ZR-KVV 450/750V Copper Conductor PvC Insulated and sheath Control Cable

Cross×Nom cross-
sectional area mm²
Nom thickness of
Insulation mm
Nom thickness of
Sheath mm
Pitch Diameter mmMax.D.C.Resistance
of Insulation at
20℃ Q-km
Max.D.C.Resistance
of 20℃ Q-km
Approx weight
(kg/km)
minmax
2×0.750.6126.48.00.01224.559
2×1.00.61.26.88.40.01118.167
2×1.50.71.27.69.40.01112.186
2×2.50.81.28.610.50.0107.41120
2×40.8129.611.50.00854.61167
2×60.81.210.512.50.00703.08220
3×0.750.61.26.88.40.01224.571
3×1.00.61.27.08.80.01118.182
3×1.50.71.28.09.80.01112.1108
3×2.50.8129.211.00.0107.41154
3×40.81.210.012.50.00854.61210
3×60.81.511.514.00.00703.08310
4×0.750.61.27.29.00.01224.5846
4×1.00.61.27.69.40.01118.1100
4×1.50.71.28.610.50.01112.1132
4×2.50.81.210.012.00.0107.41193
4×40.81.511.514.00.00854.61315
4×60.81.512.515.00.00703.08413
5×0.750.61.27.89.60.01224.599
5×1.00.61.28.210.00.01118.1116
5×1.50.71.29.411.50.01112.1154
5×2.50.81.511.514.00.0107.41243
5×40.81.512.515.00.00854.61383
5×60.81.514.016.50.00703.08505
7×0.75
7×1.0
7×1.5
7×2.5
7×4
7×6
0.6
0.6
0.7
0.8
0.8
0.8
1.2
1.2
12
1.5
1.5
1.5
8.4
9.0
10.0
12.5
13.5
15.0
10.5
11.0
12.5
15.0
16.5
18.0
0.012
0.011
0.011
0.010
0.0085
0.0070
24.5
18.1
12.1
7.41
4.61
3.08
123
146
196
211
473
652
8×0.75
8×1.0
8×1.5
8×2.5
8×4
8×6
0.6
0.6
0.7
0.8
0.8
0.8
1.2
1.2
1.2
1.5
1.5
1.5
9.4
10.0
12.0
14.0
15.5
177.5
11.5
12.0
14.5
16.5
18.0
20.0
0.012
0.011
0.011
0.010
0.0085
0.0070
24.5
18.1
12.1
7.41
4.61
3.08
142
1168
243
360
545
748
10×0.75
10×1.0
10×1.5
10×2.5
10×4
10×6
0.6
0.6
0.7
0.8
0.8
0.8
12
1.5
1.5
1.5
1.7
1.7
10.5
11.5
13.5
15.5
18.0
19.5
12.5
14.0
16.0
18.5
20.5
22.5
0.012
0.011
0.011
0.010
0.0085
0.0070
24.5
18.1
12.1
7.41
4.61
3.08
187
221
296
440
721
956
12×0.75
12×1.0
12×1.5
12×2.5
12×4
12×6
0.6
0.6
0.7
0.8
0.8
0.8
1.5
1.5
15
1.5
1.7
1.7
11.5
12.0
14.0
16.0
18.5
20.5
13.5
14.5
16.5
19.0
21.5
23.5
0.012
0.011
0.011
0.010
0.0085
0.0070
24.5
18.1
12.1
7.41
4.61
3.08
211
250
338
507
825
1026

Type KVVZRKVV450/750V Copper Conductor PVC Insulated and sheath Cable

Cross×Nom cross-

sectional area mm²

Nom thickness of 

Insulation mm

Nom thickness of

Sheath mm

Pitch Diameter mm

Max.D.C.Resistance

of Insulation at

20℃ Ω-km

Max.D.C.Resistance

of 20℃ Ω-km

Approx weight

(kg/km)

minmax
14×0.750.61.512.014.50.01224.5238
14×100.61.512.515.00.01118.1328
14×1.50.71.514.517.00.01112.1384
14×2.50.81.517.019.50.0107.41579
14×40.81.719.522.50.00854.61959
14×60.81.721.524.50.00703.081246
16×0.750.61.512.515.00.01224.52268
16×1.00.61.513.015.50.01118.1315
16×1.50.71.515.018.00.01112.1427
16×2.50.81.718.021.00.0107.41664
19×0.750.61.513.015.50.01224.5299
19×1.00.61.514.016.50.01118.1359
19×1.50.71.516.019.00.01112.1490
19×2.50.81.719.022.00.0107.41765
24×0.750.61.515.018.00.01224.5373
24×1.00.61.516.019.00.01118.1447
24×1.50.71.519.022.00.01112.1632
24×2.50.81.722.522.50.0107.41961
27×0.750.61.515.518.00.01224.5407
27×1.00.61.516.519.00.01118.1491
27×1.50.71.519.522.50.01112.1694
27×2.50.81.723.026.00.0107.411061
30×0.750.61.516.019.00.01224.5445
30×1.00.61.517.520.50.01118.1554
30×1.50.71.520.023.00.01112.1761
30×2.50.81.724.027.00.0107.411167
37×0.750.61.517.520.50.01224.5544
37×1.00.61518.521.50.01118.1658
37×1.50.71.521.525.00.01112.1908
37×2.50.81.725.529.00.0107.411401
44×0.750.61.519.523.00.01224.5642
44×1.00.61.521.024.00.01118.1777
44×1.50.71.524.528.00.01112.11074
44×2.50.82.029.533.50.0107.411702
52×0.750.61.510.023.00.01224.5737
52×1.00.61.522.025.00.01118.1896
52×1.50.71.525.529.00.01112.11243
52×2.50.82.031.035.00.0107.411973
61×0.750.61.522.025.00.01224.5843
61×1.00.61.523.026.50.01118.11027
61×1.50.71.527.531.50.01112.11468
61×2.50.82.233.037.50.0107.412306